请百度搜索 合肥中铁管业有限公司 找到我们!

技术参数

钢套钢直埋蒸汽保温管型号

文字:[大][中][小] 手机页面二维码 2018-8-3     浏览次数:    

钢套钢直埋蒸汽保温管型号


直埋蒸汽保温管的标准保温厚度
(CJ/T200-2000) T=200℃
序号 公称直径 D0 lnDW=(45*lnD0+10.88or12.66)/52.35
σ=(DW-D0)/2
DW 保温厚度
σ
1 DN50 45 0.057 -2.8647 10.88 52.35 -2.25466 0.104909 24.0
2 DN70 45 0.076 -2.57702 10.88 52.35 -2.00737 0.134341 29.2
3 DN80 45 0.089 -2.41912 10.88 52.35 -1.87164 0.153871 32.4
4 DN100 45 0.108 -2.22562 10.88 52.35 -1.70531 0.181716 36.9
5 DN125 45 0.133 -2.01741 10.88 52.35 -1.52633 0.217332 42.2
6 DN150 45 0.159 -1.83885 12.66 52.35 -1.33884 0.262149 51.6
7 DN200 45 0.219 -1.51868 12.66 52.35 -1.06362 0.345202 63.1
8 DN250 45 0.273 -1.29828 12.66 52.35 -0.87417 0.417208 72.1
9 DN300 45 0.325 -1.12393 12.66 52.35 -0.7243 0.484666 79.8
10 DN350 45 0.377 -0.97551 12.66 52.35 -0.59671 0.550618 86.8
11 DN400 45 0.426 -0.85332 12.66 52.35 -0.49168 0.611601 92.8
12 DN450 45 0.478 -0.73814 12.66 52.35 -0.39267 0.675249 98.6
13 DN500 45 0.53 -0.63488 12.66 52.35 -0.30391 0.73793 104.0
14 DN600 45 0.63 -0.46204 12.66 52.35 -0.15533 0.856131 113.1
15 DN700 45 0.72 -0.3285 12.66 52.35 -0.04055 0.960263 120.1
直埋蒸汽保温管的标准保温厚度
(CJ/T200-2000) T=250℃
序号 公称直径 D0 lnDW=(45*lnD0+16or18.6)/55.8
σ=(DW-D0)/2
DW 保温厚度
σ
1 DN50 45 0.057 -2.8647 16 55.8 -2.02351 0.132191 37.6
2 DN70 45 0.076 -2.57702 16 55.8 -1.79151 0.166709 45.4
3 DN80 45 0.089 -2.41912 16 55.8 -1.66416 0.189349 50.2
4 DN100 45 0.108 -2.22562 16 55.8 -1.50812 0.221326 56.7
5 DN125 45 0.133 -2.01741 16 55.8 -1.3402 0.261793 64.4
6 DN150 45 0.159 -1.83885 18.6 55.8 -1.14961 0.31676 78.9
7 DN200 45 0.219 -1.51868 18.6 55.8 -0.89141 0.410077 95.5
8 DN250 45 0.273 -1.29828 18.6 55.8 -0.71367 0.489843 108.4
9 DN300 45 0.325 -1.12393 18.6 55.8 -0.57306 0.563797 119.4
10 DN350 45 0.377 -0.97551 18.6 55.8 -0.45337 0.635484 129.2
11 DN400 45 0.426 -0.85332 18.6 55.8 -0.35482 0.701296 137.6
12 DN450 45 0.478 -0.73814 18.6 55.8 -0.26194 0.769554 145.8
13 DN500 45 0.53 -0.63488 18.6 55.8 -0.17867 0.836386 153.2
14 DN600 45 0.63 -0.46204 18.6 55.8 -0.03928 0.961485 165.7
15 DN700 45 0.72 -0.3285 18.6 55.8 0.068411 1.070805 175.4
直埋蒸汽保温管的标准保温厚度
(CJ/T200-2000) T=300℃
序号 公称直径 D0 lnDW=(45*lnD0+21.48or24.98)/59.5
σ=(DW-D0)/2
DW 保温厚度
σ
1 DN50 45 0.057 -2.8647 21.48 59.5 -1.80557 0.16438 53.7
2 DN70 45 0.076 -2.57702 21.48 59.5 -1.588 0.204334 64.2
3 DN80 45 0.089 -2.41912 21.48 59.5 -1.46858 0.230253 70.6
4 DN100 45 0.108 -2.22562 21.48 59.5 -1.32224 0.266538 79.3
5 DN125 45 0.133 -2.01741 21.48 59.5 -1.16476 0.311997 89.5
6 DN150 45 0.159 -1.83885 24.98 59.5 -0.9709 0.378744 109.9
7 DN200 45 0.219 -1.51868 24.98 59.5 -0.72875 0.482511 131.8
8 DN250 45 0.273 -1.29828 24.98 59.5 -0.56206 0.570032 148.5
9 DN300 45 0.325 -1.12393 24.98 59.5 -0.4302 0.65038 162.7
10 DN350 45 0.377 -0.97551 24.98 59.5 -0.31795 0.72764 175.3
11 DN400 45 0.426 -0.85332 24.98 59.5 -0.22553 0.798091 186.0
12 DN450 45 0.478 -0.73814 24.98 59.5 -0.13843 0.870725 196.4
13 DN500 45 0.53 -0.63488 24.98 59.5 -0.06033 0.941456 205.7
14 DN600 45 0.63 -0.46204 24.98 59.5 0.070393 1.07293 221.5
15 DN700 45 0.72 -0.3285 24.98 59.5 0.171383 1.186946 233.5
直埋蒸汽保温管的标准保温厚度
(CJ/T200-2000) T=350℃
序号 公称直径 D0 lnDW=(45*lnD0+28or32.5)/63.9
σ=(DW-D0)/2
DW 保温厚度
σ
1 DN50 45 0.057 -2.8647 28 63.9 -1.57921 0.206137 74.6
2 DN70 45 0.076 -2.57702 28 63.9 -1.37662 0.25243 88.2
3 DN80 45 0.089 -2.41912 28 63.9 -1.26542 0.282121 96.6
4 DN100 45 0.108 -2.22562 28 63.9 -1.12916 0.323306 107.7
5 DN125 45 0.133 -2.01741 28 63.9 -0.98252 0.374365 120.7
6 DN150 45 0.159 -1.83885 32.5 63.9 -0.78636 0.455501 148.3
7 DN200 45 0.219 -1.51868 32.5 63.9 -0.56089 0.570702 175.9
8 DN250 45 0.273 -1.29828 32.5 63.9 -0.40568 0.666525 196.8
9 DN300 45 0.325 -1.12393 32.5 63.9 -0.28289 0.753601 214.3
10 DN350 45 0.377 -0.97551 32.5 63.9 -0.17837 0.836631 229.8
11 DN400 45 0.426 -0.85332 32.5 63.9 -0.09232 0.911814 242.9
12 DN450 45 0.478 -0.73814 32.5 63.9 -0.01121 0.98885 255.4
13 DN500 45 0.53 -0.63488 32.5 63.9 0.06151 1.063441 266.7
14 DN600 45 0.63 -0.46204 32.5 63.9 0.18323 1.201091 285.5
15 DN700 45 0.72 -0.3285 32.5 63.9 0.277266 1.319518 299.8
备注: 1、管道当量埋深0.8米。
2、管道中心埋设深度DN150以内1.1米,DN150以外1.4米。
3、保温层材料在运行温度下的导热系数300度0.058W/(m*K)、350度0.063W/(m*K)。
4、土的导热系数1.5W/(m*K)。
5、直埋保温管管道周边环境温度20度。
6、工作管外表面温度,可按介质温度。
7、保温管外表面温度,按设计要求(标准50度)。
返回上一步
打印此页
0551-63628710